FAAC 746 & 844SLIDING GATE AUTOMATIONWITH CP81 CONTROLLERINSTALLATIONMANUALLatest Revision: 05.04.2004Document Ref.: 1074.D.01.0001_4
CONSULT THE ADJACENT TABLE TO DETERMINE THE CORRECT GATE WHEEL ROOT SIZE AND ROUND BAR TRACK DIAMETER REQUIRED IN RESPECT OF GATE MASS AND DUTY.GATE
400mm90155GATEWALL0 to 5044MOTOR MOUNTED RHS(VIEWED FROM INSIDE PROPERTY)225GATEWALLBASEPLATE0 to 509044MOTOR MOUNTED LHS(VIEWED FROM INSIDE PROPERTY)
102.4.3 ACCESSING CONTROLLER MODULE2.4.4 POSITIONING GEARBOXlOpen up cover of operator to allow easy access in order to feed in main supply and signal
213±350 mm2.4.6 MOUNTING OF RACK11lAttach steel rack to gate using the 25x25x2mm angle brackets (1) supplied, spaced approximately 350mm apart.lDistan
JOINING STEEL RACKWELD HEREN.B. DO NOT WELD NEAR MESHING SURFACESRACK MUST BE LEVEL200 - 300mm RACK OFFCUTMOUNTING and JOININGof NYLON RACK (RA
2.4.7 MOUNTING AND POSITIONING LIMIT SWITCH PLATES13lThe FAAC 746 & 844 operators are fitted with an inductive proximity limit switch (1). When th
3. ELECTRICAL CONNECTIONSN.B.1) FOR SINGLE PHASE FAAC 746/844 MOTORS THE CP81 CONTROLLER COMBINED WITH THE CP89 POWER SUPPLY BOARD IS USED;
15POWER WIRING DIAGRAM FOR 1 MOTOR (746 / 844)CENTURION CP89POWER SUPPLY PCB220V ACINPUT SUPPLYREDBLACKM1, M3 CABLES MAY NEEDREVERSAL DEPENDING ONRE
LSLS16POWER WIRING DIAGRAM FOR 3 MOTOR (844 3 PHASE)CENTURIONCP89INTERFACE PCBSEPARATE WEATHERPROOF ENCLOSURE OPERATOR MOUNTEDENCLOSURE4LINE 1LINE
SAFETY BEAMBEAMIRB+12VLINKNOTE - TYPICAL SAFETY BEAM IS SHOWN. REFER TO MANUFACTURER FOR DETAILSN.B. IF BEAMS ARE NOT USED THEN ENSURE THA
NOTE:INTERCOM CONNECTIONSEXAMPLE 2 BPT 1 - 1 (WITH 12V DC POWER SUPPLY)COMMAX 1 - 1 (12V)TYPICAL 220V AC POWERED INTERCOMTEGUI 12V DC INTERCOMEXAMPLE
SIGNAL COMMON0,2mmCABLE2CONTROLLERMODELCP81 LEDCOMREMOTE GATE STATUS LIGHT EMITTING DIODE (LED)COMLEDFITTED TO HANDSET BASE SEPARATELYSTATUS LEDANODE
0,2mmCABLE2CONTROLLERMODEL2 POSITION SWITCHCP81 12V LCK COMHOLIDAY LOCKOUTORORPUSHBUTTONKEYPADNB: IF HOLIDAY LOCKOUT IS NOT USED, ENSURE THAT A LINK I
LD 100 OR 101 INDUCTIVE LOOP DETECTOR IS SHOWN BELOW.MODIFY WIRING IF OTHER MAKES OF DETECTORS ARE USED.FREE EXIT LOOP -0,2mmCABLE2CONTROLLERMODELCP81
LOOP DETAILS- WIRE: 1.5mm SQUARED MULTI STRANDED CABLE (USE SILICON COATED IF PLACED DIRECTLY INTO THE GROUND)- SPACING BETWEEN TWO ADJACENT LOOPS &g
1,5mm CABLE2TRANSFORMER POWER SUPPLYCP89 cardin motor enclosureCP89 POWER SUPPLYCP81control cardTO CP81CONTROLLERTO FAACTERMINATIONBOARD12V DC SUPPLY
15mmA/F5mm4. COMMISSIONING PROCEDURE4.2 ADJUSTMENT OF ANTI - CRUSHING SYSTEM4.1 REMOVE OIL BLEED SCREW (IMPORTANT)The 746 & 844 automation systems
xxCP81CONTROLLERGREENPOWER ON12V DC SUPPLY TOCP81 CONTROLLERTO FAACTERMINATIONCARDLIMIT SWITCHCABLE TO CP81TO CP81CONTROLLERL N220V ACSUPPLYE4.3 APPLY
N.B. Procedure 1 and 2 MUST be performed on initial commissioning. Procedure 3 to 5 are required ONLY if the default settings on the
Check if limit switch wiring is correct for one of thealternatives shown belowSTATUS LED must go OFF when gate is in closed position and stopplate is
11. PRODUCT TECHNICAL DETAILS . . . . . . . . . . . . . . . . . . . . . 21.1 DIMENSIONS...21.2 TECHNICAL SPECIFICATIONS . .
If Step 1 is incorrect then swop limit switch polarity as shown below:Motors fitted with FAAC termination board(See Page 15 for wiring diagram)Motors
N.B. If direction is incorrect Stop Motor (or Remove Power) IMMEDIATELY, or serious damage could be done if gate runs into an End Stop.- Make s
Remove the electronics power from the PCB.All LED' s will extinguish.Fit SET link to PCB.Reapply power ( Reversal of STEP 1 above ). Check th
Ensure that PCB is in PROGRAMME MODE i.e. LED, L 2,MUST be illuminated (if not refer Procedure 3 ).Hold TEST P/B DOWN until LED, L 1, flashes the requ
Press & Hold TEST button while monitoring STATUS LED;Release the Pushbutton after STATUS LED Flashes the required number of times to select the re
TABLE 5.1Ensure that PCB is in PROGRAMME MODE i.e. LED, L 2,MUST be illuminated (if not refer Procedure 3).Hold TEST P/B DOWN until number of flashes
Press and Hold TEST button while counting the number oftimes STATUS LED flashes;Release the Pushbutton when the flashes count = time(or count ) requir
1. REMOVE POWER.2. FIT THE "SET" LINK.3. CONNECT "PED" AND "FRX" TO "COM".4. RECONNECT POWER. L1 AND L2 WILL I
5. MANUAL OPERATIONShould the need arise to operate the gate manually because of power failure or malfunction, release it by operating the releasing s
6. MAINTENANCE7. REPAIRSOIL LEVELPeriodically check the oil level. For medium to low duty cycles, it is advisable to perform the check annually. Where
BAC1. PRODUCT TECHNICAL DETAILSTHE FAAC 746 & 844 GATE OPERATORS ARE SELF-CONTAINED UNITS CONSISTING OF A WORMGEARED ELECTRIC MOTOR , AN ELECTRONI
CENTURIONTHE AUTOMATIC CHOICE CENTURION SYSTEMS (PTY) LTD HEAD OFFICE:TEL: +27 (0)11 699-2400, FAX: +27 (0)11 704-3412 or 462-6669 148 EPSOM AVENUE, N
1.2 TECHNICAL SPECIFICATIONSMODEL 746 844 844 3 PHASEPOWER SUPPLY 230V~ (+6% - 10%) 50Hz 230V~ (+6% - 10%) 50Hz 380V, 3 Phase 4 wire availableABSORBED
2.1 RECOMMENDED TOOLS2. PRODUCT INSTALLATIONSTEEL BITS, 3 - 12mmFLAT and RINGSPANNER8, 10, 13, 17 & 19mmSCREW DRIVER5mm FLATNo 1. PHILLIPSCRIMPIN
2.2 CABLE REQUIREMENTSG.P. = GENERAL PURPOSE HOUSE WIRING OR PANEL FLEXS.W.A. = STEEL WIRE ARMOUREDn1 = CONSULT INTERCOM SUPPLIER FOR RE
2.3 GATE REQUIREMENTSIt is important to ensure that the motor is capable of moving the gate as required. Duty cycle must be considered:MAXIMUM DUTY CY
ENSURE THAT THE GATE IS FITTED WITH CORRECT END STOPS, ETC.AS SHOWN IN THE SKETCHES BELOW.NOTE 1: The Bottom of the Round Bar (T Bar or Channel Iron