Centurion FAAC 844 Manuel d'installation Page 34

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 40
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 33
Press & Hold TEST button while monitoring STATUS LED;
Release the Pushbutton after STATUS LED Flashes the
required number of times to select the required mode.
( See Table 4.2 )
L 1 will extinguish & L 2 will illuminate allowing selection of more
functions if required.
PREFLASHING MODES:
MODE 1 - LIGHT PREFLASHES AT 1 HZ, THEN ACTS AS COURTESY LIGHT
MODE 2 - LIGHT FLASHES AT 1 HZ FOR PREFLASH TIME AND
MOTOR RUN TIME ONLY
MODE 3 - LIGHT ON CONTINUOUSLY FOR PREFLASH TIME
AND MOTOR RUN TIME ONLY
Exit PROGRAMME MODE, if NOT proceeding to procedure 5,
by removing set bridge.
STEP 3
STEP 4
Procedure 4 - Functions Selection continued
CP81
control card
CP81
control card
L1 L2
STATUS
TEST
BOTH OFF
REMOVE " SET " BRIDGE
TEST
SET
SET
FUNCTION TO BE SELECTED
REQUIRED NO. OF FLASHES OF
STATUS LED TO SELECT MODE
No. of
times
L1 is
flashing
MODE 1 MODE 2 MODE 3
STANDARD CONDOMINIUM REVERSINGPIRAC
TABLE 4.2
AUTOCLOSE ON / OFF
1 3 42
2
ON OFF
OFF
4
9
10
MODE OF OPERATION
INACTIVE
PRE - FLASHING ON / OFF
L1
L2
STATUS
32
Vue de la page 33
1 2 ... 29 30 31 32 33 34 35 36 37 38 39 40

Commentaires sur ces manuels

Pas de commentaire